Analysis of Polish eye care professionals’ opinions about deposits on contact lenses Original reaserch study

Main Article Content

Tomasz Suliński
Jacek Pniewski

Abstract

 Soft contact lenses are used worldwide to correct ametropia. This medical device should be fitted and systematically evaluated on the patient eye by eye care professionals. The examination should include an evaluation of lens deposits. The widespread use of silicone hydrogel (Si-Hy) lenses and their tendency to build up lipid deposits indicate that eye care professionals should pay special attention to this kind of deposits. This paper aims to analyze the opinions of Polish ECPs regarding deposits on contact lenses, particularly regarding lipids and Si-Hy lenses. Data were collected from 103 Polish eye care professionals through an online survey. Respondents reported that lipid deposits are most often present on Si-Hy lenses, and protein deposits occur most often on hydrogel lenses. Almost all of them declare that they evaluate deposits on contact lenses on follow-up visits, which concludes that this is an essential part of the lens selection process for them. Respondents believe that different lenses and lens care solutions vary in the context of their interaction with lipid deposits. These parameters should be considered at the time of product selection. Eye care professionals expect descriptions of lenses’ resistance to lipid deposits, and care solution effectiveness in reducing lipid deposits.

Downloads

Download data is not yet available.

Article Details

How to Cite
1.
Suliński T, Pniewski J. Analysis of Polish eye care professionals’ opinions about deposits on contact lenses. Ophthatherapy [Internet]. 2021Nov.30 [cited 2024Dec.22];8(4):255-62. Available from: https://journalsmededu.pl/index.php/ophthatherapy/article/view/1593
Section
Conservative treatment

References

1. Morgan PB, Woods CA, Tranoudis IG et al. International contact lens prescribing in 2020. Contact Lens Spectr. 2021: 32-8.
2. Millar TJ, Schuett BS. The real reason for having a meibomian lipid layer covering the outer surface of the tear film – A review. Exp Eye Res. 2015; 137: 125-38. http://doi.org/10.1016/j.exer.2015.05.002.
3. Zhou L, Zhao SZ, Koh SK et al. In-depth analysis of the human tear proteome. J Proteomics. 2012; 75(13): 3877-85. http://doi.org/10.1016/J.JPROT.2012.04.053.
4. Yokoi N, Bron AJ, Georgiev GA. The precorneal tear film as a fluid shell: The effect of blinking and saccades on tear film distribution and dynamics. Ocul Surf. 2014; 12(4): 252-66. http://doi.org/10.1016/j.jtos.2014.01.006.
5. McCulley JP, Shine W. A compositional based model for the tear film lipid layer. Trans Am Ophthalmol Soc. 1997; 95: 79-88; discussion 88-93.
6. Mann A, Tighe B. Contact lens interactions with the tear film. Exp Eye Res. 2013; 117: 88-98. http://doi.org/10.1016/j.exer.2013.07.013.
7. Cheung SW, Cho P, Chan B et al. A comparative study of biweekly disposable contact lenses: Silicone hydrogel versus hydrogel. Clin Exp Optom. 2007; 90(2): 124-31. http://doi.org/10.1111/j.1444-0938.2006.00107.x.
8. Nichols JJ. Deposition on silicone hydrogel lenses. Eye Contact Lens 2013: 39: 20-3. http://doi.org/10.1097/ICL.0b013e318275305b.
9. Suliński T, Pniewski J. Interaction of silicone hydrogel contact lenses with lipids – a chronological review. OphthaTherapy. 2020; 7(4): 306-25. http://doi.org/10.24292/01.OT.311220.A.
10. Efron N. History. In: Efron N. Contact Lens Practice. 2018; 3-9.e1. http://doi.org/10.1016/b978-0-7020-6660-3.00001-0.
11. Wagner H. The How and Why of Contact Lens Deposits. Review of Cornea & Contact Lens. Published 2020. https://www.reviewofcontactlenses.com/article/the-how-and-why-of-contact-lens-deposits.
12. Tsukiyama J, Miyamoto Y, Fukuda M et al. Influence of Cosmetic and Cleansing Products for the Eyes on Soft Contact Lenses. IOVS. ARVO Journals. Published 2010 (access: 22.10.2021).
13. Tavazzi S, Rossi A, Picarazzi S et. Polymer-interaction driven diffusionof eyeshadow in soft contact lenses. Contact Lens Anterior Eye. 2017; 40(5): 335-9. http://doi.org/10.1016/j.clae.2017.06.003.
14. Luensmann D, Yu M, Yang J et al. Impact of cosmetics on the physical dimension and optical performance of silicone hydrogel contact lenses. Eye Contact Lens. 2015; 41(4): 218-27. http://doi.org/10.1097/ICL.0000000000000109.
15. Standard badania optometrycznego i dopasowania soczewek kontaktowych (access: 22.10.2021).
16. Jones L, Senchyna M, Glasier MA et al. Lysozyme and lipid deposition on silicone hydrogel contact lens materials. Eye Contact Lens. 2003; 29(suppl 1): S75-9. http://doi.org/10.1097/00140068-200301001-00021.
17. Maziarz EP, Stachowski MJ, Liu XM et al. Lipid Deposition on Silicone Hydrogel Lenses, Part I: Quantification of Oleic Acid, Oleic Acid Methyl Ester, and Cholesterol. Eye Contact Lens Sci Clin Pract. 2006; 32(6): 300-7. http://doi.org/10.1097/01.icl.0000224365.51872.6c.
18. Nash WL, Gabriel MM. Ex vivo analysis of cholesterol deposition for commercially available silicone hydrogel contact lenses using a fluorometric enzymatic assay. Eye Contact Lens. 2014; 40(5): 277-82. http://doi.org/10.1097/ICL.0000000000000052.
19. Nash W, Gabriel MM, Mowrey-McKee M. A comparison of various silicone hydrogel lenses; Lipid and protein deposition as a result of daily wear. American Academy of Ophthalmology (AAO); 2010 (access: 22.10.2021).
20. Luensmann D, Omali NB, Suko A et al. Kinetic Deposition of Polar and Non-polar Lipids on Silicone Hydrogel Contact Lenses. Curr Eye Res.Curr Eye Res. 2020; 45(12): 1477-1483. http://doi.org/10.1080/02713683.2020.1755696.
21. Shows A, Redfern RL, Sickenberger W et al. Lipid Analysis on Block Copolymer-containing Packaging Solution and Lens Care Regimens: A Randomized Clinical Trial. Optom Vis Sci. 2020; 97(8): 565-72. http://doi.org/10.1097/OPX.0000000000001553.